Delabie GROUP termostadi ventiil 3/4" PREMIX COMFORT 55L 32°C to 42°C
Kaubamärk:
Ühik: tk
Tarneaeg: 14-21päeva
Proovi kupongikoodi PEGU-KEVAD ! Vali toode täishinnaga, lisa see ostukorvi ja sisesta kupongikood ostu sooritamisel! Kupongikoodi kasutamise aeg on piiratud!
Lugupeetud PEGU.EE veebipoes külastajad!
Tere tulemast meie internetipoes! Me ei ole lihtsalt iseteeninduse kassa. Kui teil on vaja nõu või abi toote valimisel, võtke meiega julgesti ühendust kas e-mailiga või messendzeriga, telefoni teel. Oleme alati valmis pakkuma teile personaalset teenindust! Täname külastuse eest!
PEGU.EE meeskond
PREMIX COMFORT
Ref. 731002
Group thermostatic mixing valve for mixed water distribution from 32° - 42°C:
Anti-scalding safety.
Regulates temperature variations.
Filters and non-return valves can be accessed from the outside without removing the mechanism.
Thermal shock with no specific lever needed (push-button on the control knob).
Interchangeable cartridge with automotive cell.
High-resistance chrome-plated brass body.
Maximum hot water temperature: 85°C.
Differential hot water / mixed water: 15°C minimum.
Pressure difference at the inlets: 1 bar maximum (0.5 bar recommended).
Minimum pressure / maximum: 1 - 10 bar (1 - 5 bar recommended).
Left hand side hot water inlet (red ring) and right hand side cold water inlet (blue ring).
Mixed water outlet at the top (purple ring).
For bottom outlet: unscrew / place lid at the top and outlet connector at the bottom.
Maximum temperature limiter, can be adjusted by the installer.
Reduced risk of scalding by limiting temperature at the point-of-use.
55 lpm - M3/4".
Failid
> Working pressure :
1 to 5 bar
> Flow :
6 l/min with integrated flow limiter Anti-water-hammering device
Rotating shower head with anti-limescale spikes
> Flow time :
30 seconds (± 5 sec.)
> Hydraulic supply :
G 1/2" (15x21), top or rear water inlet. For rear water inlet, we recommend to use the adaptation kit under the reference 91026. On ALPA S® NF IB mixer tap with NF check valves
> Material :
Anodised aluminium extruded section (2.5mm thickness) Aluminium removable valve plate, peinted RAL 7005 colour High resistance RAL 7005 coloured ABS covers
> Functioning:
Wide opening panel without the need to dismantle from the wall and shower taps on a removable valve plate
> Thermal resistance :
Resistant to a temperature of 75°C for 30-minute-thermal-shocks
> Security :
Adjustable tamper-proof temperature limiter to prevent scalding
Patented anti-blocking "S" system preventing the water flows continuously
> Delivered with :
1/2" hoses with revolving nuts
MM 1/2" (15x21) straight stop valves and 250 micron filters Fastening screws and instruction manual
> Standards & approvals :
Brass body in accordance with EN 1982, EN 12164, EN 12165 Chrome-plated surface treatment in accordance with EN 12540 200-hour neutral salt spray resistant (NSS) in accordance with ISO 9227
Complete assembling kit including pedal tap and spout
It includes: pedal tap art. 02061, spout art. 02024, water connections with flexibles, check valves with filter
Complete assembling kit including single pedal mixer and spout
It includes: single pedal mixer art. 02070, spout art. 02026, water connections with flexible tubes, check valves with filter
PREMIX SECURITY
Ref. 731053
Group thermostatic mixing valve for hot water circulating loops adjustable from 44°C to 58°C:
Anti-scalding safety.
Regulates temperature variations.
Non-return valves and filters accessible from the exterior without having to remove the mechanism.
Thermal cartridge with no specific lever needed (push-button on the control knob).
Interchangeable cartridge with thermostatic cell.
High-resistance chrome-plated brass body.
Maximum hot water temperature: 85°C.
Differential hot water / mixed water: 15°C mini.
Pressure differences at the entrance: 1 bar maximum (0.5 bar recommended).
Minimum pressure / maximum: 1 to 10 bar (1 to 5 bar recommended).
Left hand side hot water inlet (red ring) and right hand side cold water inlet (blue ring).
Mixed water outlet at the top (purple ring) for bottom outlet: unscrew / place lid at the top and outlet connector at the bottom.
15% energy savings: optimised heat loss (comparison between a circulating loop at 55°C and a non-circulating system at 70°C).
Safety and prolongation of system life span (Hot water at >65°C leads to premature aging within the system).
Maximum temperature limiter, can be adjusted by the installer.
Reduced risk of scalding by limiting temperature at the point-of-use.
90 lpm - M1".